Neuscan Static sEMG 肌電圖軟體

A new technology based on non-invasive surface electromyography (sEMG) and computer based analysis of sEMG data collected from the spinal area, is now available for back rehabilitation specialists. This technology is visually orientated to help health care providers quickly obtain an objective picture of muscle activity with minimal training and to get patients involved in their treatment.

NeuScan allows you to:

  • Demonstrate muscle imbalance between one side and the other across the spine to identify possible subluxations & dysfunction.
  • Assess areas of paraspinal muscles compared to normative data base and demonstrate areas of hyperactivity.
  • Involve patients in treatment by showing areas of concern.
  • Use installed charts, showing relationship between various segmental levels and affected tissues & organs to graphically demonstrate a patient's areas of hyperactivity and potential dysfunction.
  • Produce an automated patient report showing these details in a format that is useful for patient education, and as a monitoring tool, for patient care and in reporting cases to insurance companies and attorneys.

 

Features:

 

  • Colorful visual feedback
  • Type your own notes in reports
  • Intuitive screens
  • Print previous patient reports
  • Comes with standard patient reports

As well as providing visual feedback that is easy for your patient to understand, the software provides the following:

 

  • Automated data collection protocol
  • Left / right % differences calculated
  • Signal stability by standard deviation
  • Color coded by magnitude of difference
  • Standard reports can be edited using any word processor, and can be printed in color
  • Patient insurance & referral source records database

 

Technical Specifications

  • Number of patients: Unlimited
  • Number of Channels Supported: 1 or 2
  • Sample Rate per Channel: 100 / Sec. Typical - user selectable
  • Scan Period: 1 - 1000 Sec.; user selectable
  • Signal Variability Check: Std. Dev. 0 - 1000; user selectable
  • Works with all of NeuroDyne Instruments

 

System Requirments:

  • Any NeuroDyne computer based instrument.
  • PC or with 486 or higher processor
  • Windows 95 or 98
  • 8M or more memory
  • 10 MB of free Hard Disk space
  • 3.5” Floppy or CDRom Drive
  • sVGA or better monitor